COAE thresholds .1. Effects of equal-amplitude versus subtraction methods |
Author(s):
Journal/Book: J Speech Lang Hear Res. 1997; 40: 10801 Rockville Pike, Rockville, MD 20852-3279. Amer Speech-Language-Hearing Assoc. 1164-1176.
Abstract: Although research has demonstrated that click-evoked otoacoustic emissions (COAEs) elicited by high-level stimuli are useful for identifying hearing loss, the ability of COAEs to predict behavioral thresholds has not been adequately tested. Results of studies comparing COAE thresholds and behavioral thresholds have been equivocal, perhaps due to the need for a more rigorous approach to COAE threshold estimation. The present study was designed to address several methodological concerns in COAE threshold testing, particularly the effects of two methods of stimulus presentation on COAE testing and threshold calculation. In on attempt to make COAE threshold estimation consistent across participants, COAE threshold calculations were based on mean noise floor levels across participants. COAE and noise floor levels were measured in 15 participants using both equal-amplitude clicks and a subtraction method. Broadband COAEs were analyzed into 1/3 octave bands, so that input/output functions could be examined and COAE thresholds could be calculated for each 1/3 octave band. Comparison of the two stimulus methods indicated several differences. Mean noise floor levels for the equal-amplitude method were approximately 6 dB lower than those measured For the subtraction method across frequency. In many cases COAEs evoked using the equal-amplitude method were higher in amplitude than those evoked using the subtraction method. COAE thresholds measured using the equal-amplitude click stimuli were significantly lower than those measured using the subtraction method. The significantly higher thresholds obtained using the subtraction method may be attributed in part to the reduction of COAE amplitude by the subtraction procedure, and not merely to the higher noise level. Slopes of the input/output functions were not significantly different between the two stimulus methods. These results suggest that the equal-amplitude method is preferable for COAE threshold resting because lower noise floor and larger amplitude COAEs may be obtained in the same test time.
Note: Article Prieve BA, Syracuse Univ, Dept Commun Sci & Disorders, 805 S Crouse Ave, Syracuse,NY 13244 USA
Keyword(s): otoacoustic emissions; thresholds; otoacoustic emission methods; EVOKED OTOACOUSTIC EMISSIONS; SENSORINEURAL HEARING-LOSS; ACOUSTIC EMISSIONS; AUDITORY-SYSTEM; EARS
© Top Fit Gesund, 1992-2024. Alle Rechte vorbehalten – Impressum – Datenschutzerklärung